Traditional TRV Twin Pack Pewter

  • £37.00

Only -89 left!

Application

Traditional Thermostatic Radiator Valve set - perfect for a traditional style radiator such as a cast iron radiator. Thermostatic Radiator Valves (TRVs) provide local control of room temperatures to maintain comfort and save energy. TRVs sense the air temperature around them and control the flow of water through the radiator to which they are fitted, to maintain and limit the temperature within the room.
By providing local temperature control in every room, TRVs can significantly improve comfort for householders by providing better heat distribution around a dwelling.
A lockshield valve sits on the other end of the radiator to the TRV and provides one way of balancing the flow of water through the radiator so that the overall system performance is maximised. Once set by your installer, they should not be tampered with or adjusted again as this may affect the efficiency and performance of your heating system.

Features

  • Using Vernet-made wax sensors to provide consistent and longer lasting performance
  • All valve bodies allow bi-directional water flow which means that valves can be installed without the need to adjust the insert flow direction after installation
  • Quiet operation
  • Comply to European Standard EN 215
  • 10 bar rating suitable for combi boilers
  • Matching lockshiled radiator valve

Material

    • Pewter brass head
    • Pewter brass connection bell
    • Internal wax filled metal sensor
    • Pewter brass valve body
    • Pewter brass union nuts and radiator tailpiece

    Specification

    • Setting range :                            16 – 30°C
    • Closing dimension:                     11.5 mm
    • Maximum Water Temperature:    120°C
    • Maximum Water Pressure:          10 bar
    • Maximum Differential Pressure:  1.0 bar
    • Nominal flow:                               192 kg/h
    • Hysteresis:                                   0.3

     Temperature setting range

    Temperature setting range of traditional TRV

     

     

    Code Connections Finishing
    8211PE 15mm x 1/2” Angled Black 1 20

     

    Dimensions (mm)

    diagram of Traditional TRV Twin Pack

    Maintenance

    The bodies, thermostatic head and lockshield cover should be cleaned using a mild soap solution.
    Do not use abrasive pads, bleach or solvents etc as they will damage the surfaces.